MJ-VR430 Dual-channel shell vibration monitor

MJ-VR430 Dual-channel shell vibration monitor DSP system installed, is a precision intelligent measurement and control instrument, widely used in electric power, petroleum, chemical and other departments. Through the magnetic-electric sensor the instrument can continuously monitor and measure the peak-peak value for the vibration of the steam turbine, wind turbine and other rotating machine. With alarm and shutdown control signal output, equipped with current output and RS485 interface, it can connect with computers and other devices and synchronize with PLC equipments. The Monitor uses an 80 × 160 (mm) common chassis, LED digital display, PVC color mask and light touch keys, it has a European standard resolution of 128*64 on the display with beautiful appearance, novel style, reasonable structure, simple installation, stable performance and reliable quality.

Skontaktuj się z nami >>
  • Opis
  • specyfikacje
  • Wybór parametrów
  • Cecha
  • Zapytanie ofertowe

MJ-VR430 Dual-channel shell vibration monitor DSP system installed, is a precision intelligent measurement and control instrument, widely used in electric power, petroleum, chemical and other departments. Through the magnetic-electric sensor the instrument can continuously monitor and measure the peak-peak value for the vibration of the steam turbine, wind turbine and other rotating machine. With alarm and shutdown control signal output, equipped with current output and RS485 interface, it can connect with computers and other devices and synchronize with PLC equipments. The Monitor uses an 80 × 160 (mm) common chassis, LED digital display, PVC color mask and light touch keys, it has a European standard resolution of 128*64 on the display with beautiful appearance, novel style, reasonable structure, simple installation, stable performance and reliable quality.

1. Główne funkcje

1.1 ma dwa kanały, każdy kanał może mierzyć i wyświetlać amplitudę drgań.

1.2 Posiada 4 dwukanałowe przełączanie sterujące sygnałami. Za pomocą miniaturowego przekaźnika dużej mocy maksymalne napięcie przełącznika wynosi 440 VAC / 125 V DC, maksymalny prąd przełącznika wynosi 16 A, maksymalna moc przełącznika wynosi 4000 VA, mechaniczna odporność na ciśnienie wynosi 10 milionów razy. Poprzez ustawienie dolnej wartości alarmowej, górnej wartości alarmowej, opóźnienia opóźnienia i dolnej wartości niebezpiecznej, górnej wartości niebezpiecznej, opóźnienia opóźnienia, odpowiednie działanie, gdy amplituda drgań osiągnie wartość zadaną przełącznik przekaźnika przechodzi w stan roboczy.

1.3 Dual 4 ~ 20mA isolation high precision current transmission output, with high precision voltage reference inside, 18 digits precision voltage drive chip, high precision and low drift

operational amplifier, guarantee the accuracy of the output reach 0.01%. By the main range lower limit setting and main range upper limit setting of the menu item, divide it into the corresponding

current interval of 4 ~ 20mA accurately, so that improves the accuracy of output signal. Calibrate the lower limit and upper limit of current loop by current meter, then demarcate the linearity of 4 ~ 20mA more accurate.

1.4 Urządzenie ma wyświetlacz głównego zakresu, wyświetlacz procentowy, wykres słupkowy, wyświetlacz prądu transmisji. Bardziej wygodne, szybkie i dokładne dla klientów jest przeprowadzanie kalibracji w aplikacji na miejscu.

2.1 Signal Input: YD9200 Vibration speed Sensor/YD30 acceleration sensor/YD33 Piezoelectric velocity sensor/BN330500

2.2 Range of measurement: Range 0~200μm*, 0~300μm, 0~500μm,0~1000μm(p-p)

Prędkość 0~10mm/s, 0~20mm/s*, 0~50mm/s ,0~100mm / s

according to users' needs to determine the range, "*" is the default range

2.3 Measurement accuracy: Linear error ≤ ± 1% (full -scale value)

2.4 Display performance: 128*64 Dot matrix LCD display

2.5 Frequency Response: 5~1000Hz

2.6 Frequency -response errors:40~60Hz ≤±1%; 30~120Hz ≤±2%; 14~200Hz ≤±4%.

2.7 Output currrent: 4 ~ 20mA or RS485

2.8 Setting method:Touch setting

2.9 Alarm contact capacity: 440VAC / 125VDC, maximum switched current is 16A.

2.10 Working temperature: Temperature: -20 ℃ ~ 70 ℃

Relative humidity: ≤ 85%

2.11 Power Supply: Alternating current:220VAC ± 30% 50Hz /60Hz Power consumption:≤ 20W

2.12 Dimension: 80 × 165 × 275mm

2.13 Hole Size: 73 × 152mm

2.14 Range of measurement:≤ 2000um(p-p)

3.Operating Instructions:

1.Connect power:

Please connect the display device to power before using it .The system will start to operation after 5 seconds and the display shown in Figure 3:

Rysunek 3

2. Parameter settings:

①Touch "SET" button, enter the password input operation interface, see Figure 4

Rysunek 4

Hasło systemowe :6808

Finished entering the password, press "OK button", if the password is correct, you can enter the parameter setting interface, shown in Figure 5:

Rysunek 5

White section shows the initial value of each parameter, touch the white section, you can select the item you want to set the parameters, and then enter the parameter setting value interface, see Figure 6:

Rysunek 6

Please enter the correct value. If the input is complete, press "OK button". If there are other

parameters need to be modified, repeat the previous operation, modify the relevant parameters.Please remember to touch “Save”(in the top right of the screen) in Figure 5, then the parameters are modified.

After pressing "Save", the system saves the new value and return to work status.

4. MJ-VR430 Vibration Monitor plate connection

1)ⅠLine

Signal input -: come port,connect with YD9200 Vibration Sensor or YD30 accelerometer.

Signal input +:sygnał wejściowy,connect with YD9200 Vibration Sensor or YD30 accelerometer.

Current -: 4~20mA Current output negative terminal, connect with come port, external load≤500Ω.

Current +:4~20mA Current output positive terminal,external load ≤500Ω.

AlarmⅠ:Relay output, open circuit between two normal points, mesns resistance is infinite,AlarmⅠ brighten,relay closed,zero resistance between two points.

AlarmⅡ:Relay output, open circuit between two normal points, mesns resistance is infinite,AlarmⅡ brighten,relay closed,zero resistance between two points.

2)Ⅱ Line

Signal input -:come port,connect with Vibration Sensor.

Signal input +:sygnał wejściowy,connect with Vibration Sensor.

Current -:4~20mA Current output negative terminal, connect with come port, external load≤500Ω.

Current +:4~20mA Current output positive terminal,external load ≤500Ω.

AlarmⅠ:Relay output, open circuit between two normal points, mesns resistance is infinite,AlarmⅠ brighten,relay closed,zero resistance between two points.

AlarmⅡ:Relay output, open circuit between two normal points, mesns resistance is infinite,AlarmⅡ brighten,relay closed,zero resistance between two points.

AC220V:Alternating current 220V

:GND(G),connect with ground,never be able to connect with come port.

Vibration speed sensor installation:

Installation site:Horizontal or vertical mounted on the measured vibration points,fixed sensor with M10 * 1.5 screws.

Wymagania instalacyjne:Need to install the lateral file board protection sensor.

According the color of the line to distinguish the positive and negative pole (red line is positive pole,the blue one is negative pole) .

5.Remark

Guarantee system is not in the state of alarm, when set interface.

M4 screws used to fix the sensor.

Product warranty for 1 year, lifelong maintenance.

MJ-VR430-A□□-B□□-C□□-D□□-E□□